1999 Toxicology in Vitro 1999 Apr ;13 (2):355-373
Univ Stirling, Microbiol Associates Ltd, Stirling FK9 4LA, Scotland. Procter & Gamble Co, Miami Valley Labs, Human Safety Dept, Cincinnati, OH 45253 USA. Natl Food Agcy Denmark, Inst Toxicol, DK-2860 Soeborg, Denmark. McPherson, JP, Hill Top Globe Crown I

The performance of the tissue equivalent assay using the Skin(2TM) ZK1200 model in the COLIPA International Validation Study on Alternatives to the Draize Eye Irritation Test

The tissue equivalent assay (TEA) (Osborne et al., 1995) was used to evaluate 55 mixed ingredients and formulations in the COLIPA International Validation Study on Alternatives to the Draize Rabbit Eye Irritation Test (Brantom et at, 1997). The TEA can be used to test all types of materials since it uses a topical application approach and is not limited to only testing liquid or soluble materials. A prediction model (PM) for the test was developed using historical eye irritation data from a total of 132 materials on which in vivo and in vitro data were available. A regression model was derived from these data and used to relate the in vitro endpoint (t(50)) obtained in the study to a Draize MMAS (modified maximum average score). This provided a measure of the predicted in vivo eye irritation scores. In the current study, two separate laboratories used the same protocol to test the same set of coded materials and the results of both laboratories were compared to the initial PM. The TEA met the reliability criteria of the validation study in reproducing the predefined PM in both laboratories, and a good relationship between predicted and observed Draize MMAS values was obtained (r = 0.906 and r = 0.850). Good correlations were maintained when separate analyses were made of the formulations and ingredients included in the test set. Good relationships between the in vitro endpoint and individual Draize tissue scores (r>0.8) were also exhibited. Although insufficient data were available to make an assessment of interlaboratory variation, some difference in the reproducibility of the assay was noted between the two laboratories, particularly for the highly irritating materials. However, the consistency of data was encouraging and the discrepancies seen between the laboratories suggested a sensitivity of the model to subtle differences in application techniques, and in handling and timing. Taken together, these results indicate the utility of the TEA test for these types of substances and the need to more fully address the issue of interlaboratory reproducibility. (C) 1999 Elsevier Science Ltd. All rights reserved.